Correlation between Inferior Vena Cava Diameter Assessed on Ultrasonography and Central Venous Pressure among Critically ILL Patients Admitted In Intensive Care Unit

Welcome to DSpace BU Repository

Welcome to the Bahria University DSpace digital repository. DSpace is a digital service that collects, preserves, and distributes digital material. Repositories are important tools for preserving an organization's legacy; they facilitate digital preservation and scholarly communication.

Show simple item record

dc.contributor.author Shabih Zehra
dc.contributor.author Atif Latif
dc.contributor.author Asiya Kazi
dc.contributor.author Syed Ijaz Hussain Zaidi
dc.date.accessioned 2020-07-23T06:06:31Z
dc.date.available 2020-07-23T06:06:31Z
dc.date.issued 2020-07-01
dc.identifier.issn 2220-7562
dc.identifier.uri http://hdl.handle.net/123456789/9326
dc.description.abstract Objective: To assess the correlation between inferior vena cava(IVC) diameter and central venous pressure (CVP) in critical patients admitted in ICU. Study Design and Setting: The cross-sectional pilot study was conducted at Radiology Department of PNS SHIFA Hospital. Methodology: 18-80 years patients were included and patients with severe orthopnea, unable to lie in supine position, morbid obese, pneumothorax, mass in mediastinum, tricuspid regurgitation and intra-cerebral bleeds were excluded. Results: The mean age of 50 patients was 41.44±16.73 years. Mean measurement of CVP was considered as 10.41±4.18 mm. Mean diameter of IVC was 12.65±2.22 mm. The study results showed weak negative correlation between the CVP and IVC (r= - 0.110, p=0.04). It was also predicted that patients with age =50 years showed weak negative correlation between the CVP and IVC (r=-0.290, p=0.034). Similarly, in patients with age >50 years there was strong negative correlation between CVP and IVC (r=-0.680, p=0.045). The study results also showed that in male patients there was weak negative correlation between the CVP and IVC i.e. (r=-0.045, p=0.048). However, in female patients there was moderate positive correlation (r=0.685, p=0.001). Conclusion: Weak negative correlation was found between inferior vena cava diameter on ultrasonography and central venous pressure measurement among critically ill patients en_US
dc.description.sponsorship JBUMDC en_US
dc.language.iso en en_US
dc.publisher Bahria University Medical and Dental College Karachi en_US
dc.relation.ispartofseries 03;10
dc.subject central venous pressure, inferior vena cava en_US
dc.title Correlation between Inferior Vena Cava Diameter Assessed on Ultrasonography and Central Venous Pressure among Critically ILL Patients Admitted In Intensive Care Unit en_US