Modeling and Simulation of Phasor Measurement Unit (PMU) for Early Fault Detection in Interconnected Two-Area Network

Welcome to DSpace BU Repository

Welcome to the Bahria University DSpace digital repository. DSpace is a digital service that collects, preserves, and distributes digital material. Repositories are important tools for preserving an organization's legacy; they facilitate digital preservation and scholarly communication.

Show simple item record

dc.contributor.author Asad Waqar
dc.contributor.author Zeeshan Khurshid
dc.contributor.author Jehanzeb Ahmad
dc.contributor.author Muhammad Aamir
dc.contributor.author Muneeb Yaqoob
dc.contributor.author Imtiaz Alam
dc.date.accessioned 2018-12-03T11:16:49Z
dc.date.available 2018-12-03T11:16:49Z
dc.date.issued 2018
dc.identifier.uri http://hdl.handle.net/123456789/7814
dc.description.abstract The electrical power system is becoming more and more complex with the increasing demand of the electricity across the world, as the world is becoming the global village. The electrical power system must be reliable and safe enough to fulfil the energy requirements with the continuous supply of energy. The chances of power system’s blackouts and outages are increasing with its increased complexity. So, there is a need of an efficient control system to make the power system more safe, efficient and reliable. Wide Area Monitoring, Protection and Control system (WAMPAC) is becoming an emerging technology for an efficient monitoring, protection and control of power system. Phasor measurement unit (PMU) is an integrated part of wide area monitoring, protection and control (WAMPAC) system, which can be used for monitoring, protection and control of complex electrical power systems. PMU gives the synchronized phasor measurements of voltage and current and can easily monitor and control even small disturbances in power system to protect the power system from any blackouts and outages before any fault occurs. In the proposed paper a PMU model is designed in MATLAB/Simulink and then PMU is used for power system protection and the comparative analysis are done with the conventional protection technique for an interconnected two-area network power system. en_US
dc.language.iso en en_US
dc.publisher Bahria University Islamabad Campus en_US
dc.subject Department of Electrical Engineering en_US
dc.title Modeling and Simulation of Phasor Measurement Unit (PMU) for Early Fault Detection in Interconnected Two-Area Network en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account