Welcome to the Bahria University DSpace digital repository. DSpace is a digital service that collects, preserves, and distributes digital material. Repositories are important tools for preserving an organization's legacy; they facilitate digital preservation and scholarly communication.
dc.contributor.author | Tahir Anwar, 01-244151-023 | |
dc.date.accessioned | 2018-04-17T11:38:41Z | |
dc.date.available | 2018-04-17T11:38:41Z | |
dc.date.issued | 2015 | |
dc.identifier.uri | http://hdl.handle.net/123456789/5942 | |
dc.description | Supervised by Dr. Asad Waqar | en_US |
dc.description.abstract | During these days, as more electronic devices came into use and the percentage of nonlinear load increases, due to this harmonics have become the basic power quality problem in power system. Just to solve the problem in the power system, we must be aware of the harmonic sources and must prevent its related problem. In our country Pakistan, with many other crises, energy crisis is also the serious one. This is because of the increasing demand and low supply of the electricity which is other words is known as the load shedding. This is also one of the reason that actually moved many industries while residential consumers have come towards the vast use of energy back up supply, Uninterruptable Power Supplies (UPSs) and Generators to avoid inconvenience. Electronic switches based power converters used in Uninterruptable power supplies (UPSs) generates harmonics which effect the performance and reduce life of power system equipment’s. In this thesis, harmonic distort caused by Uncontrolled rectifier used in Uninterrupted power supply under different loads will be analyzed to measure the total harmonic distortion produced in distribution system. Also passive filter and shunt active power filter are used to limits the harmonics with in IEEE standards. Simulation results will show harmonic distortion caused by different loads with rectifier, compensation with PF and SAPF and effects on grid transformer utilization. Also comparison is made in term %THD which filter does minimized THD effectively. MATLAB SIMULINK will be used to develop and analyze the model. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Electrical Engineering, Bahria University Engineering School Islamabad | en_US |
dc.relation.ispartofseries | MS EE;T-0414 | |
dc.subject | Electrical Engineering | en_US |
dc.title | Harmonic analysis of converter fed distribution system (T-0414) (MFN 6201) | en_US |
dc.type | Thesis | en_US |