DSpace Repository

Evaluation of Gram Stain Error Rates of Clinical Specimens

Show simple item record

dc.contributor.author Rabia Sajjad, Gohar Zaman
dc.contributor.author Irfan Ali Mirza, Wajid Hussain
dc.contributor.author Umar Khurshid, Asim Shehzad
dc.date.accessioned 2024-09-11T06:09:42Z
dc.date.available 2024-09-11T06:09:42Z
dc.date.issued 2021-03-17
dc.identifier.uri https://doi.org/10.51253/pafmj.v72i6.5814
dc.identifier.uri http://hdl.handle.net/123456789/17871
dc.description Senior Professor HOD Dr. Gen. Irfan Mirza, BUCM, Department of Pathology
dc.description.abstract Objective: To determine important errors in initial Gram staining of clinical specimens and evaluate the types of Gram-stain errors. Study Design: Cross-sectional study. Place and Duration of Study: Microbiology Department, Armed Forces Institute of Pathology, Rawalpindi Pakistan, from Aug 2018 to Feb 2019. Methodology: Gram staining and culture inoculation of all specimens were performed per recommended guidelines. The Gram stain results on day-0 were compared with the results of the culture on day-2. There was no discrepancy if similar organisms were obtained on culture as on Gram stain. Nevertheless, if the Gram stain and culture results were not similar, it was termed a discrepancy. The consultant microbiologist reviewed all discrepant slides, and if not resolved, possible causes of error were sought, and the results documented. Results: Of the total 300 clinical specimens, errors were observed in the initial gram staining of 29 specimens (9.7%), whereas 271(90.3%) specimens were error-free. Upon evaluating these 29 errors, 11(38.0%) were observer errors which were resolved when reviewed by a consultant microbiologist. 14(48.0%) were technical errors, and 4(14.0%) results were discrepant due to the presence of anaerobic organisms, missed on initial aerobic cultures. Conclusion: The frequency of Gram stain errors in our study (9.7%) is not very high; nevertheless, it can have severe consequences in critical samples from seriously ill patients if wrong empirical antimicrobial treatment is begun based on a wrong initial Gram stain result. en_US
dc.language.iso en en_US
dc.publisher Pak Armed Forces Medical Journal en_US
dc.subject Clinical specimens, Errors, Gram stain en_US
dc.title Evaluation of Gram Stain Error Rates of Clinical Specimens en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record