Feature Extraction from Retinal Images for Diagnosis of Diabetic Retinopathy

Welcome to DSpace BU Repository

Welcome to the Bahria University DSpace digital repository. DSpace is a digital service that collects, preserves, and distributes digital material. Repositories are important tools for preserving an organization's legacy; they facilitate digital preservation and scholarly communication.

Show simple item record

dc.contributor.author Saad Javed, 01-113072-033
dc.contributor.author Tahir Sarfaraz, 01-113072-036
dc.date.accessioned 2023-08-22T07:08:28Z
dc.date.available 2023-08-22T07:08:28Z
dc.date.issued 2011
dc.identifier.uri http://hdl.handle.net/123456789/16033
dc.description Supervised by Mr. Usman Akram en_US
dc.description.abstract There is an ever-increasing interest in the development of automatic medical diagnosis systems due to the advancement in computing technology and also to improve the service by medical community. The knowledge about health and disease is required for reliable and accurate medical diagnosis. Digital information is acquired at different scales, quickly and efficiently by means of image processing techniques. So the algorithms can be developed for computer-aided medical diagnosis based on image processing technology. In this project,. a design and algorithms of a digital diabetic retinopathy system for the screening of diabetic retinopathy is proposed. The proj ect proposes algorithms for retinal image preprocessing, blood vessel enhancement and segmentation, and optic disk localization and detection. The developed methods are tested on three different publicly available databases i. e. DRIVE, STARE, Diaretdb. Four parameters are used to check the validity of proposed algorithms i.e. visual inspection, accuracy, area under the receiver operating curves (ROC) and calculation time. The proposed method for preprocessing achieves an average accuracy of 98.04% whereas proposed method fo r vessel segmentation achieves an average accuracy of94.85% and an average area under the receiver operating characteristic curve of 0.9669. The algorithm for optic disk achieves an average accuracy of 96.7% for localization. The proposed methods are compared with recently published methods and experimental results show that proposed methods outperform all others. en_US
dc.language.iso en en_US
dc.publisher Computer Sciences en_US
dc.relation.ispartofseries BS (ETM);P-01765
dc.subject Feature Extraction en_US
dc.subject Retinal Images en_US
dc.subject Diagnosis of Diabetic Retinopathy en_US
dc.title Feature Extraction from Retinal Images for Diagnosis of Diabetic Retinopathy en_US