<?xml version="1.0" encoding="UTF-8"?>
<feed xmlns="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/">
<title>Department of Earth &amp; Environmental Science (BUES)</title>
<link href="http://hdl.handle.net/123456789/10322" rel="alternate"/>
<subtitle/>
<id>http://hdl.handle.net/123456789/10322</id>
<updated>2026-11-14T13:17:32Z</updated>
<dc:date>2026-11-14T13:17:32Z</dc:date>
<entry>
<title>Removal of Selected Pharmaceutical Compounds from Aqueous Media Using Granular Activated Carbon(Gac) Filter</title>
<link href="http://hdl.handle.net/123456789/21677" rel="alternate"/>
<author>
<name>Umair Saeed, 01-167222-008</name>
</author>
<author>
<name>Maryum Gulalay, 01-167222-007</name>
</author>
<id>http://hdl.handle.net/123456789/21677</id>
<updated>2026-09-03T09:59:12Z</updated>
<published>2026-01-01T00:00:00Z</published>
<summary type="text">Removal of Selected Pharmaceutical Compounds from Aqueous Media Using Granular Activated Carbon(Gac) Filter
Umair Saeed, 01-167222-008; Maryum Gulalay, 01-167222-007
Pharmaceutical compounds, including the non-steroidal anti-inflammatory drugs (NSAIDs) diclofenac and ibuprofen, are increasingly detected in water bodies globally, raising serious concerns about their ecological and public health impacts. Because conventional wastewater treatment systems are largely ineffective at removing these persistent micropollutants, low-cost decentralized alternatives are urgently required. This study designed and evaluated a simple, gravity-driven granular activated carbon (GAC) fixed-bed adsorption column for the removal of diclofenac and ibuprofen from synthetic aqueous solutions. The column was constructed from a plastic syringe packed with sequential layers of cotton, gravel and sand. Stock solutions of 1000 mg/L were prepared and diluted to working concentrations of 5 mg/L, 25 mg/L, and 50 mg/L. The effects of initial concentration, solution pH, contact time, and water matrix (distilled versus tap water) on removal efficiency were systematically investigated using UV-Visible spectrophotometry. The GAC column achieved a maximum removal efficiency of 97.1% for diclofenac at 50 mg/L in distilled water. For both target compounds, removal efficiency scaled positively with higher initial concentrations and extended contact times. Adsorption was highly pH-dependent; both compounds exhibited preferential removal under acidic conditions below their respective p�� values, where the molecules exist in an uncharged form that favors hydrophobic interaction with the carbon matrix. Conversely, tap water trials demonstrated a decline in performance due to competitive adsorption from co-existing dissolved matrix substances. Comparatively, diclofenac consistently outperformed ibuprofen across all experimental configurations due to its higher hydrophobicity and stronger interactions with the activated carbon surface. Ultimately, these findings contribute directly to SDG 3 and SDG 6 by demonstrating the technical feasibility of an electricity-free, low-cost approach to emerging contaminant remediation
Supervised by Dr. Asma Jamil
</summary>
<dc:date>2026-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>2d Structural Interpretation and Petrophysical Analysis of Sawan Area Lower Indus Basin, Pakistan</title>
<link href="http://hdl.handle.net/123456789/21676" rel="alternate"/>
<author>
<name>Arooba Farooq, 01-166232-005</name>
</author>
<author>
<name>Zoha Tariq, 01-166222-019</name>
</author>
<id>http://hdl.handle.net/123456789/21676</id>
<updated>2026-09-03T09:41:31Z</updated>
<published>2026-01-01T00:00:00Z</published>
<summary type="text">2d Structural Interpretation and Petrophysical Analysis of Sawan Area Lower Indus Basin, Pakistan
Arooba Farooq, 01-166232-005; Zoha Tariq, 01-166222-019
The research purpose is to map out the subsurface structure of an area and investigate the fluid properties through well logs to understand and identify hydrocarbonprone zones and justify the drilling locations. First, our obtained data was matched with the interpretation datum. Structural analysis is carried out by performing horizon interpretation, fault interpretation, and contour mapping on C-Interval of the Lower Goru Formation. The hydrocarbon bearing zones are interpreted using seismic sections and validated through Petrophysical analysis of all available wells. The study revealed normal faults forming a structure, horst and graben systems like negative flower structure, with fault orientations trending northwest to southeast. The contour map indicates the structural inclination and fault-bounded closures near the well locations. Fault seal analysis further confirmed that these faults provide suitable structural closure for hydrocarbon accumulation. Bright spots were identified at the C Interval of the Lower Goru Formation. Petrophysical analysis on available wells showed hydrocarbon saturation exceeding 55% within the C-Interval of the Lower Goru Member. Four potential reservoir zones areas were identified in Sawan-02 well and two zones in Sawan-07 well based on their integrated interpretation of seismic and well-log data. The results indicate that the area of interest possesses favorable reservoir characteristics, including good permeability, effective structural closure, and strong hydrocarbon potential
Supervised by Mr. Masood Anwar
</summary>
<dc:date>2026-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>Evaluation of Pulmonary Function Among a Pharmaceutical Occupational Cohort in Islamabad, Pakistan</title>
<link href="http://hdl.handle.net/123456789/21773" rel="alternate"/>
<author>
<name>Syeda Iman Sara, 01-167222-013</name>
</author>
<id>http://hdl.handle.net/123456789/21773</id>
<updated>2026-10-06T13:26:17Z</updated>
<published>2026-01-01T00:00:00Z</published>
<summary type="text">Evaluation of Pulmonary Function Among a Pharmaceutical Occupational Cohort in Islamabad, Pakistan
Syeda Iman Sara, 01-167222-013
Occupational exposure to active pharmaceutical ingredient (API) dust, excipient powders, solvent vapors and antibiotic aerosols is a chronic exposure in the pharmaceutical manufacturing industry, which has not been extensively studied for its occupational respiratory health effects in Pakistan. The present study is a cross-sectional study aimed to assess pulmonary function and health related quality of life (HRQoL) among a pharmaceutical occupational cohort in Islamabad. A total of 78 workers from a pharmaceutical manufacturing plant in Humak Industrial Sector, Islamabad were recruited. Standardized measurements of pre- and postbronchodilator spirometry were made according to ATS/ERS 2019 guidelines: Forced Vital Capacity (FVC), Forced Expiratory Volume in 1 second (FEV₁), FEV₁/FVC ratio and Peak Expiratory Flow (PEF). The ventilatory patterns were determined according to the accepted diagnostic criteria, and the obstructive cases were further divided by GOLD criteria and bronchodilator reversibility. The validated St. George's Respiratory Questionnaire (SGRQ) was used to measure HRQoL. Pearson correlation (α = 0.05) was used to explore associations between work duration, smoking status, BMI and spirometric outcomes. The cohort had a mean age of 31.6 ± 11.2 years (56.4% female), mean BMI of 21.7 ± 4.2 kg/m², and mean occupational tenure of 5.1 ± 4.1 years. In total, 62.8% showed ventilatory impairment: obstructive (33.3 %), restrictive (23.1 %) and mixed (6.4 %). Of those who were obstructive, 65.4% fulfilled GOLD criteria for COPD and 34.6% had reversible asthma-like obstruction. Mean SGRQ Activity domain score (28.6 ± 14.0) exceeded Symptoms (22.5 ± 14.2) and Impacts (14.5 ± 14.2) scores. Spirometric parameters were positively correlated with smoking (confounded by sex). Within the relatively short tenure studied no significant correlation was found between occupational duration and lung function. There is a significant level of ventilatory impairment among this pharmaceutical manufacturing workforce that is much higher than that reported among other comparable occupational groups in Pakistan. This indicates that there are multiple pathophysiological mechanisms at play, as there is a higher proportion of obstructive rather than restrictive4 patterns and both fixed COPD-pattern and reversible asthma-type obstruction were identified. The present results support the notion of the implementation of compulsory, periodic spirometric surveillance in pharmaceutical manufacturing industry and highlight the importance of further occupational respiratory health studies in this industry in Pakistan.
Supervised by Dr. Fiza Sarwer
</summary>
<dc:date>2026-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>Removal of Pharmaceutical Compounds Mefenamic Acid and Naproxen from Aqueous Media by Using Granular Activated Carbon (Gac) in a Fixed Bed Column System</title>
<link href="http://hdl.handle.net/123456789/21548" rel="alternate"/>
<author>
<name>Sabahat Baseer Abbasi, 01-167222-010</name>
</author>
<author>
<name>Fatima Shehreen, 01-167222-004</name>
</author>
<id>http://hdl.handle.net/123456789/21548</id>
<updated>2026-08-03T05:07:10Z</updated>
<published>2026-01-01T00:00:00Z</published>
<summary type="text">Removal of Pharmaceutical Compounds Mefenamic Acid and Naproxen from Aqueous Media by Using Granular Activated Carbon (Gac) in a Fixed Bed Column System
Sabahat Baseer Abbasi, 01-167222-010; Fatima Shehreen, 01-167222-004
Pharmaceutical compounds including non-steroidal anti-inflammatory drugs such as mefenamic acid and naproxen are increasingly detected in water bodies globally, raising serious concerns about their ecological and public health impacts. Conventional wastewater treatment systems are largely ineffective at removing these micropollutants from water sources. This study designed and evaluated a simple gravity-driven granular activated carbon fixed-bed adsorption column for the removal of mefenamic acid and naproxen from synthetic aqueous solutions. The column was constructed from a plastic syringe packed with layers of cotton, gravel, silica sand, and GAC with dimensions of 1 cm gravel, 4 cm sand, and 4 cm GAC respectively. Stock solutions of 1000 mg/L were prepared from pharmaceutical tablets and diluted to working concentrations of 5 mg/L, 25 mg/L, and 50 mg/L. The effects of initial concentration, solution pH (acidic and basic conditions), contact time, and water matrix type (distilled and tap water) on removal efficiency were systematically investigated. All samples were analyzed by UV-Visible spectrophotometry at 270 nm. The column achieved a maximum removal efficiency of 97.1% for mefenamic acid at 50 mg/L in distilled water. Removal efficiency increased with higher initial concentration and longer contact time for both pharmaceutical compounds. Mefenamic acid showed preferential removal under acidic conditions while naproxen performed marginally better under basic conditions above its pKa charge state. Tap water experiments showed reduced removal efficiency compared to distilled water due to competitive adsorption by dissolved matrix substances. Mefenamic acid consistently outperformed naproxen under all experimental conditions due to its higher hydrophobicity and stronger affinity for the activated carbon surface. The findings contribute to SDG 6 and SDG 3 by demonstrating the technical feasibility of a low-cost, electricityfree approach to pharmaceutical water treatment
Supervised by Dr. Asma Jamil
</summary>
<dc:date>2026-01-01T00:00:00Z</dc:date>
</entry>
</feed>
